Nickel is one of the world’s most important engineering metals, valued for its exceptional corrosion resistance, Aukštos temperatūros našumas, excellent alloying characteristics, and unique magnetic properties.
It plays a critical role in industries ranging from aerospace and electronics to chemical processing, atsinaujinančios energijos, Medicinos prietaisai, and precision manufacturing.
Whether used in stainless steel, superlydiniai, rechargeable batteries, or electromagnetic components, nickel contributes properties that few other metals can simultaneously provide.
Among these properties, magnetizmas often raises questions. Many people know that iron is magnetic, while copper and aluminum are not.
Nickel occupies an interesting position because it is one of only three elemental metals that are naturally ferromagnetic at room temperature, together with iron (Fe) ir kobalto (Co).
Tačiau, the magnetic behavior of nickel is more complex than a simple yes or no.
Factors such as alloy composition, temperatūra, kristalų struktūra, Šaltas darbas, and heat treatment can significantly alter its magnetic performance.
1. Is Nickel Magnetic?
What Is Nickel?
Nikelis (chemical symbol Į, atominis skaičius 28) is a silvery-white transition metal belonging to Group 10 periodinės lentelės.
It possesses an excellent combination of corrosion resistance, Tvirtumas, ausmingumas, Elektrinis laidumas, ir šiluminis stabilumas, making it one of the most widely used alloying elements in modern industry.
| Nuosavybė | Vertė |
| Chemical Symbol | Į |
| Atominis skaičius | 28 |
| Kristalinė struktūra | Kubinis į veidą (FCC) |
| Atominis svoris | 58.69 g/mol |
| Tankis | 8.90 g/cm³ |
| Lydymosi taškas | 1455° C. (2651° F.) |
| Virimo taškas | 2913° C. (5275° F.) |
| Šilumos laidumas | 90.9 W/m · k |
| Elektrinis laidumas | Maždaug 22% IACS |
| Elektros varža | 6.99 × 10⁻⁸ Ω·m |
| Šilumos išsiplėtimo koeficientas | 13.4 × 10⁻⁶ /k |
| Savitoji šilumos talpa | 444 J/kg · k |
Short Answer: Yes—Nickel Is Naturally Ferromagnetic
The simple answer is taip.
Pure nickel is naturally ferromagnetic kambario temperatūroje. This means it can:
- Be strongly attracted by permanent magnets.
- Become magnetized under an external magnetic field.
- Retain a portion of its magnetization after the external field is removed.
- Form magnetic domains that align to produce a permanent magnetic field.
Nickel belongs to an exclusive group of elemental metals that exhibit spontaneous ferromagnetism under normal conditions.
| Elementas | Naturally Ferromagnetic at Room Temperature | Curie temperatūra |
| Lygintuvas (Fe) | Taip | 770° C. |
| Kobaltas (Co) | Taip | 1,115° C. |
| Nikelis (Į) | Taip | 358° C. |
Above its Curie temperature, nickel no longer behaves as a ferromagnetic material and instead becomes paramagnetinis, responding only weakly to external magnetic fields.

Why Nickel Is Magnetic
The magnetism of nickel arises from its electronic structure—specifically, the arrangement of electrons in its 3d orbital. Nickel has the electron configuration [Ar] 3d⁸ 4s².
This means there are two unpaired electrons in the 3d subshell. These unpaired electrons create a net magnetic moment.
When the magnetic moments of adjacent atoms align in the same direction, the material becomes ferromagnetic.
This alignment is driven by a quantum mechanical phenomenon called the exchange interaction, which favours parallel alignment of electron spins in certain metals.
In nickel, the exchange interaction is strong enough to maintain parallel spin alignment up to 358°C (the Curie temperature).
2. Understanding Magnetism in Metals
What Is Magnetism?
Magnetism is a physical phenomenon arising from the motion and spin of electrons within atoms.
Every electron generates a tiny magnetic field, but whether a material exhibits noticeable magnetism depends on how these atomic magnetic moments interact collectively.
In most metals, individual magnetic moments either pair with opposite spins or remain randomly oriented, resulting in little or no observable magnetism.
In ferromagnetic materials such as nickel, Tačiau, neighboring atomic moments interact strongly enough to align spontaneously over large regions, producing a measurable magnetic field.
Major Types of Magnetic Materials
| Tipas | Apibrėžimas | Magnetic Behaviour | Pavyzdžiai |
| Feromagnetinis | Stipri trauka; retains magnetisation; magnetic moments align parallel. | High susceptibility; isterezė; magnetic domains. | Lygintuvas, Nikelis, kobaltas, ir jų lydiniai. |
| Ferrimagnetic | Stipri trauka; magnetic moments align antiparallel but unequally. | Similar to ferromagnetic but weaker. | Magnetite (Fe₃O4), ferrites. |
| Antiferomagnetinis | Very weak attraction; magnetic moments align antiparallel. | Susceptibility increases with temperature. | Chromas, manganese oxides. |
Paramagnetinis |
Very weak attraction; no retention; moments align with external field. | Susceptibility decreases with temperature (Curie law). | Aliuminis, platina, titanas. |
| Diamagnetinis | Labai silpnas atstūmimas; no permanent moments; induced moments oppose field. | Susceptibility is negative. | Vario, švino, bismuth, vanduo. |
3. Why Nickel Is Ferromagnetic
Nickel’s ferromagnetism is rooted in the principles of quantum mechanics rather than classical electromagnetism.
Unlike ordinary metals, nickel possesses an electronic structure that allows millions of atomic magnetic moments to cooperate and align over large regions, creating a strong macroscopic magnetic field.
This phenomenon results from the combined effects of electron spin, exchange interactions, kristalų struktūra, and magnetic domain formation.

Atomic Structure of Nickel
Nickel atoms contain 28 electrons arranged around a nucleus of 28 protons.
While the inner electrons are tightly bound and contribute little to magnetic behavior, the outer 3d electrons play a decisive role.
Nickel crystallizes in a į veidą orientuotas kubinis (FCC) lattice at room temperature.
This highly ordered atomic arrangement places neighboring nickel atoms close enough for their electron wave functions to overlap, enabling strong magnetic interactions throughout the crystal.
Electron Configuration
The ground-state electron configuration of nickel is:
[Ar] 3d⁸ 4s²
The partially filled 3d orbital contains unpaired electrons, each possessing an intrinsic magnetic moment due to electron spin.
If these moments remained randomly oriented, the material would exhibit only weak paramagnetism. Vietoj, nickel’s atomic structure allows neighboring spins to interact cooperatively.
Exchange Interaction
The key mechanism responsible for nickel’s ferromagnetism is the exchange interaction, a quantum mechanical effect arising from the overlap of neighboring electron wave functions.
This interaction favors parallel alignment of adjacent electron spins because it minimizes the total energy of the crystal. Dėl to:
- Neighboring atomic magnetic moments align spontaneously.
- Large regions of uniformly magnetized atoms develop.
- Magnetization exists even without an external magnetic field.
Although the magnetic moment of an individual nickel atom is smaller than that of iron, the collective alignment of billions of atoms generates significant magnetic behavior.
Magnetic Domains
To reduce overall magnetic energy, nickel does not behave as one giant magnet.
Vietoj, it is divided into numerous microscopic magnetic domains, each containing millions of atoms with their magnetic moments aligned in the same direction.
In an unmagnetized piece of nickel:
- Domains point in different directions.
- Their magnetic fields largely cancel one another.
- The material exhibits little external magnetism.
When exposed to an external magnetic field:
- Favorably oriented domains expand.
- Domain walls move.
- Atomic spins rotate toward the applied field.
- Overall magnetization increases rapidly.
If the magnetic field is sufficiently strong, most domains become aligned, and the nickel approaches magnetic saturation.
Curie temperatūra
Nickel remains ferromagnetic only below its Curie temperatūra, apytiksliai 358° C. (631 K).
Below this temperature:
- Exchange interactions dominate.
- Magnetic domains remain stable.
- Strong ferromagnetic behavior is maintained.
Above the Curie temperature:
- Thermal energy disrupts spin alignment.
- Magnetic domains collapse.
- Nickel transitions into a paramagnetinis medžiaga, exhibiting only weak magnetism in an external field.
This temperature-dependent transition is a critical consideration in applications involving elevated operating temperatures, such as electric motors, generatoriai, Jutikliai, and high-temperature industrial equipment.
4. Factors Affecting Nickel’s Magnetism
Although pure nickel is inherently ferromagnetic, its magnetic behavior is not constant under all service conditions.
The strength of magnetization, magnetinis pralaidumas, and magnetic stability can change significantly depending on temperature, lydinio sudėtis, mechanical processing, Mikrostruktūra, and the surrounding operating environment.
Temperatūra
Temperature is the most influential factor affecting the magnetism of nickel.
Kylant temperatūrai, thermal energy causes greater atomic vibration, gradually disrupting the alignment of magnetic domains responsible for ferromagnetism.
Below its Curie temperatūra (approximately 358°C / 676° F.), nickel maintains spontaneous magnetization and exhibits strong ferromagnetic behavior.
As the temperature approaches the Curie point, magnetic permeability and saturation magnetization decrease rapidly.
Once the Curie temperature is exceeded, the magnetic domains collapse, and nickel undergoes a phase transition from a ferromagnetic material to a paramagnetic one.
In this state, it responds only weakly to an external magnetic field and no longer retains permanent magnetization.
Svarbu, ši transformacija yra grįžtama. If the material is cooled below the Curie temperature without undergoing significant microstructural changes or oxidation, its ferromagnetic properties are restored.
| Temperatūros diapazonas | Magnetinis elgesys | Inžinerinės pasekmės |
| Below 300°C | Stable ferromagnetism | Suitable for most magnetic components |
| 300–358°C | Magnetism gradually weakens | Reduced magnetic efficiency |
| Above 358°C | Paramagnetinis | Not suitable for magnetic applications |
| After cooling below Curie point | Ferromagnetism recovers | Magnetic properties are generally restored |
Lydinio sudėtis
The addition of alloying elements has a profound effect on nickel’s magnetic characteristics because it alters the electronic structure and crystal lattice.
Tokie elementai kaip lygintuvas ir kobaltas generally enhance ferromagnetic behavior by increasing magnetic exchange interactions, while alloying additions including Chromas, molibdenas, Manganas, Vario, ir silicio tend to reduce magnetic permeability by stabilizing non-magnetic phases or disrupting magnetic domain alignment.
Todėl, nickel alloys exhibit a wide spectrum of magnetic behavior.
Nickel-iron alloys such as Permalloy are specifically engineered to achieve extremely high magnetic permeability for transformers, magnetinis ekranavimas, and precision sensors.
Priešingai, high-performance corrosion-resistant alloys such as Inconel, Hastelloy, and many grades of Monel are designed primarily for mechanical and chemical performance, resulting in weak or nearly non-magnetic characteristics.
This explains why nickel content alone cannot be used to predict whether an alloy will be strongly magnetic.
Crystal Structure and Microstructure
The magnetic behavior of nickel is closely related to its face-centered cubic (FCC) crystal structure and the arrangement of magnetic domains within the material.
Grūdelių dydis, grain orientation, fazių pasiskirstymas, nusėda, and crystal defects all influence the movement of magnetic domain walls.
Materials with uniform grains and low internal stress generally exhibit more stable and predictable magnetic performance, whereas heterogeneous microstructures can reduce magnetic permeability and increase magnetic hysteresis.
During manufacturing processes such as casting, kalimas, riedėjimas, arba terminis apdorojimas, changes in grain morphology and residual stress modify the domain structure, leading to measurable variations in magnetic properties even when the chemical composition remains unchanged.
Cold Working and Residual Stress
Mechanical deformation introduced during cold rolling, Piešimas, lenkimas, štampavimas, or machining changes the internal stress distribution of nickel and affects the mobility of magnetic domains.
Cold work increases dislocation density and residual stress, creating obstacles that impede domain-wall motion.
Dėl to, coercivity often increases while magnetic permeability decreases. In precision electromagnetic components, excessive cold deformation can reduce magnetic efficiency and increase hysteresis losses.
Dėl šios priežasties, many high-performance magnetic nickel alloys undergo stress-relief annealing after fabrication to restore optimal magnetic characteristics and improve dimensional stability.
Terminis apdorojimas
Terminis apdorojimas influences nickel’s magnetism by relieving residual stress, refining grain structure, and modifying phase distribution.
Proper annealing promotes grain growth and reduces internal lattice distortion, allowing magnetic domains to move more freely.
This generally increases magnetic permeability and decreases coercive force.
Ir atvirkščiai, inappropriate heat-treatment temperatures or cooling rates may introduce undesirable phases or residual stresses that adversely affect magnetic performance.
For nickel-iron soft magnetic alloys, precisely controlled annealing cycles are a critical manufacturing step, often determining the final magnetic properties more significantly than the alloy composition itself.
Applied Magnetic Field
Nickel does not exhibit a fixed magnetic intensity under all operating conditions. Its response depends on both the strength and history of the applied magnetic field.
When an external magnetic field is introduced, magnetic domains progressively rotate and align with the field direction, causing magnetization to increase until saturation is reached.
Beyond the saturation point, further increases in field strength produce little additional magnetization.
After the external field is removed, a portion of the magnetization remains as remanence, while the field required to eliminate this residual magnetization is known as the coercive force.
These characteristics are represented by the material’s hysteresis loop and are particularly important in the design of motors, pavaros, magnetic sensors, and electromagnetic devices.
Veikimo aplinka
The service environment can indirectly influence nickel’s long-term magnetic performance.
Although nickel possesses excellent corrosion resistance, prolonged exposure to elevated temperatures, ciklinė šiluminė apkrova, oxidizing atmospheres, mechanical vibration, or aggressive chemicals may gradually alter the surface condition and microstructure.
These changes can affect magnetic stability over extended service periods, especially in demanding industrial environments.
In applications such as aerospace systems, jūrų įranga, chemijos perdirbimo įmonės, and power-generation facilities, engineers evaluate both magnetic properties and environmental durability simultaneously to ensure reliable long-term performance.
Gamybos procesas
Different manufacturing methods produce distinct microstructures and residual stress states, resulting in variations in magnetic behavior.
Cast nickel components generally contain larger grains and slower solidification structures, while forged products exhibit refined grains and improved mechanical properties.
Cold-finished materials possess higher residual stresses, whereas annealed products typically demonstrate greater magnetic permeability and lower coercivity.
Surface finishing processes such as apdirbimas, šlifavimas, poliravimas, and electroplating usually have little direct effect on bulk magnetism, but they can influence magnetic performance in high-precision instruments where extremely tight magnetic tolerances are required.
5. Are Nickel Alloys Magnetic?
One of the most common misconceptions is that every alloy containing nickel must be magnetic.
In reality, nickel content alone does not determine magnetic behavior.
Vietoj, magnetism depends primarily on:
- Kristalinė struktūra
- Lydinio sudėtis
- Phase distribution
- Terminis apdorojimas
- Šaltas darbas
- Tarnavimo temperatūra
As alloying elements modify nickel’s atomic arrangement, they also alter the exchange interactions responsible for ferromagnetism.
Magnetic Behavior of Common Nickel Alloys
| Lydinys | Nikelio turinys | Mikrostruktūra | Magnetic at Room Temperature | Tipiškos programos |
| Nikelis 200 | ≥99.0% | FCC | Taip | Elektriniai komponentai, Cheminė įranga |
| Nikelis 201 | ≥99.0% (Žemas anglis) | FCC | Taip | Maisto apdorojimas, Elektronika |
| Monel 400 | ~63–70% Ni | Nickel-Copper | Slightly magnetic to weakly magnetic | Marine engineering, Siurbliai, vožtuvai |
| Monel K-500 | ~63% Ni | Precipitation-hardened | Weakly magnetic | Offshore shafts, tvirtinimo detalės |
| Inconel 600 | ~72% Ni | Austenitinis | Paprastai nemagnetinis (atkaitintas) | Šilumokaičiai, krosnys |
Inconel 625 |
~58% Ni | Austenitinis | Iš esmės nemagnetinis | Aviacijos ir kosmoso, Jūrų, Cheminis apdorojimas |
| Inconel 718 | ~52% Ni | Precipitation-hardened | Slightly magnetic after aging | Aircraft engines, turbinos |
| Hastelloy C-276 | ~57% Ni | Austenitinis | Nemagnetinis (atkaitintas) | Cheminio apdorojimo įranga |
| Lydinys 20 | ~35% In | Austenitinis | Nemagnetinis | Sulfuric acid service |
| Nimonic 80A | ~75% Ni | Nickel superalloy | Šiek tiek magnetinis | Dujų turbinos, aviacijos ir kosmoso |
6. How to Test Whether Nickel Is Magnetic
Determining whether nickel or a nickel-containing alloy is magnetic is important in material identification, kokybės kontrolė, alloy verification, and equipment maintenance.
While a simple magnet can provide a quick indication, engineering applications often require quantitative measurements of magnetic permeability, magnetinio srauto tankis, or saturation magnetization.
| Testing Method | Tikslumas | Quantitative | Non-Destructive | Tipiškos programos |
| Permanent magnet | Žemas | Ne | Taip | Quick field identification |
| Magnetic permeability meter | Aukštas | Taip | Taip | Industrial quality control |
| Gauss meter | Aukštas | Taip | Taip | Magnetic field measurement |
| Vibrating Sample Magnetometer (VSM) | Labai aukštas | Taip | Taip | Materials research, lydinio vystymas |
| SQUID magnetometer | Extremely High | Taip | Taip | Scientific research |
| Magnetic Force Microscopy (MFM) | Microscopic | Taip | Taip | Domain structure analysis |
7. Industrial Applications of Magnetic Nickel
Nickel’s unique combination of feromagnetizmas, atsparumas korozijai, mechaninis patvarumas, ir šiluminis stabilumas makes it indispensable in numerous industrial sectors.
Skirtingai nuo geležies, nickel maintains excellent corrosion resistance while still exhibiting useful magnetic behavior, making it ideal for harsh environments where conventional magnetic materials would rapidly deteriorate.

Electric Motors and Generators
Nickel is commonly used in electromagnetic components that require stable magnetic performance under repeated magnetization cycles.
Programos apima:
- Motor pole components
- Rotor assemblies
- Magnetic shielding
- Generator components
- Electromagnetic actuators
Electromagnetic Relays and Solenoids
Nickel’s relatively high magnetic permeability enables efficient magnetic flux transmission.
Įprastos programos apima:
- Relay armatures
- Solenoid cores
- Electromagnetic switches
- Contact systems
- Industrial control equipment
Magnetic Sensors
Many sensing technologies rely on nickel’s stable magnetic behavior.
Programos apima:
- Hall-effect sensors
- Proximity sensors
- Position sensors
- Current transformers
- Speed measurement systems
Rechargeable Batteries
Nickel is a key material in numerous battery technologies.
Pavyzdžiai apima:
- Nickel-metal hydride (NiMH)
- Nickel-cadmium (NiCd)
- Nickel-rich lithium-ion cathodes
- Battery current collectors
Electronic Components
Electroplated nickel coatings serve both protective and functional purposes.
Įprastos programos apima:
- Printed circuit boards (PCB)
- Jungtys
- Semiconductor packages
- Shielding enclosures
- Precision contacts
Aviacijos ir kosmoso pramonė
Nickel-based alloys are extensively used in aircraft and spacecraft because they retain mechanical strength at elevated temperatures.
Tipiški komponentai apima:
- Turbine engines
- Išmetimo sistemos
- Tvirtinimo detalės
- Jutikliai
- High-temperature electromagnetic devices
Cheminio apdorojimo įranga
Pure nickel combines magnetic properties with excellent corrosion resistance against alkaline chemicals.
Typical equipment includes:
- Siurbliai
- Vožtuvai
- Šilumokaičiai
- Slėginiai indai
- Electrochemical reactors
Medicinos įranga
Nickel-containing magnetic materials are found in numerous medical devices.
Pavyzdžiai apima:
- Diagnostic instruments
- MRI-compatible auxiliary components
- Surgical equipment
- Precision actuators
- Laboratory automation
Magnetic Shielding
Nickel-containing alloys are widely used for electromagnetic interference (EMI) apsauga.
Programos apima:
- Elektroniniai korpusai
- Communication equipment
- Aerospace electronics
- Industrial automation
- Precision instrumentation
8. Nickel vs Other Magnetic Metals
Nors lygintuvas (Fe), kobaltas (Co), ir Nikelis (Į) are the three naturally occurring ferromagnetic metals at room temperature, they differ significantly in magnetic performance, Mechaninės savybės, atsparumas korozijai, temperature stability, ir pramoniniai pritaikymai.
| Nuosavybė | Nikelis (Į) | Lygintuvas (Fe) | Kobaltas (Co) | Feritinis nerūdijantis plienas (430) | Martensitinis nerūdijantis plienas (410) |
| Kristalinė struktūra (Kambario temperatūra) | FCC | BCC | HCP | BCC | BCT |
| Magnetinis elgesys | Feromagnetinis | Feromagnetinis | Feromagnetinis | Feromagnetinis | Feromagnetinis |
| Curie temperatūra | 358° C. | 770° C. | 1,115° C. | ~700–750°C | ~700–760°C |
| Relative Magnetic Permeability | Vidutinis - aukštas | Labai aukštas | Aukštas | Vidutinis - aukštas | Vidutinis |
| Saturation Magnetization | Vidutinis | Labai aukštas | Aukštas | Vidutinis | Vidutinis |
| Atsparumas korozijai | Puiku | Vargšas | Gerai | Gerai | Vidutinis |
Atsparumas nusidėvėjimui |
Gerai | Vidutinis | Puiku | Gerai | Puiku (Termiškai apdorotas) |
| Aukštos temperatūros stabilumas | Gerai | Vidutinis | Puiku | Gerai | Vidutinis |
| Aparatas | Gerai | Vidutinis | Sunku | Gerai | Gerai |
| Santykinė medžiagų kaina | Vidutinis | Žemas | Labai aukštas | Vidutinis | Vidutinis |
| Tipiškos programos | Cheminė įranga, Elektronika, galvanizavimas | Transformatoriai, variklius, konstrukcinis plienas | Aviacijos ir kosmoso, nuolatiniai magnetai, turbinos komponentai | Buitinė technika, išmetimo sistemos, magnetic housings | Vožtuvai, Siurbliai, Turbinos ašmenys |
9. Common Myths About Nickel Magnetism
| Myth | Fact |
| All nickel‑based alloys are magnetic. | Netiesa. Many nickel alloys (Pvz., Inconel, Monel, Hastelloy) are non‑magnetic or weakly magnetic due to dilution of the ferromagnetic structure by other elements. |
| Nickel loses magnetism forever when heated. | Netiesa. Nickel’s magnetism returns when cooled below its Curie temperature (358° C.), provided the material has not undergone a phase change. |
Nickel is the most magnetic metal. |
Netiesa. Iron has a higher magnetic moment per atom and higher saturation magnetisation. Nickel is the third most magnetic elemental metal (after iron and cobalt). |
| Nickel is magnetic at all temperatures. | Netiesa. Above 358°C, nickel becomes paramagnetic. Below 358°C, it is ferromagnetic. |
| The magnet test can distinguish nickel from other metals. | Partially false. The magnet test can indicate ferromagnetism, but it cannot distinguish between nickel, lygintuvas, ir kobalto. Further tests (Pvz., cheminė analizė, tankis) būtini. |
10. Išvada
Nickel occupies a unique position among engineering metals because it combines natural ferromagnetism, Išskirtinis atsparumas korozijai, Puikus lankstumas, and reliable high-temperature performance.
As one of the three elemental metals that exhibit ferromagnetism at room temperature, nickel plays a vital role in applications ranging from electromagnetic devices and sensors to chemical processing equipment and advanced aerospace systems.
Tačiau, magnetic behavior in nickel is more nuanced than a simple magnetic or non-magnetic classification.
Pure nickel is distinctly ferromagnetic, but its magnetic strength is lower than that of iron. Be to, lydinio sudėtis, terminis apdorojimas, Šaltas darbas, darbinė temperatūra, and microstructure all have a significant influence on magnetic performance.
For engineers and designers, selecting the appropriate nickel material requires balancing multiple factors, including magnetic permeability, Mechaninis stiprumas, atsparumas korozijai, Gamyba, eksploatacinės temperatūros, ir gyvenimo ciklo kaina.
In demanding industrial environments where corrosion resistance and dependable magnetic properties must coexist, nickel remains one of the most versatile and valuable engineering materials available.
DUK
Is pure nickel magnetic at room temperature?
Taip. Pure nickel is ferromagnetic at room temperature (20° C.) and remains so up to its Curie temperature of 358°C.
Are all nickel alloys magnetic?
Ne. The magnetic behaviour of nickel alloys depends on the alloying elements and their concentrations.
Many nickel alloys (Pvz., Inconel, Monel, Hastelloy) are non‑magnetic or weakly magnetic.
How does nickel’s magnetism compare to iron?
Nickel has a lower magnetic moment per atom (0.6 μ_B vs. 2.2 μ_B for iron) and lower saturation magnetisation (0.6 T vs. 2.15 T). Iron is more strongly magnetic than nickel.
Can nickel be made non‑magnetic?
Taip. Alloying nickel with sufficient non‑magnetic elements (Pvz., Vario, Chromas, titanas) can dilute the ferromagnetic lattice and produce non‑magnetic or weakly magnetic alloys.
What is the most magnetic nickel alloy?
Permalloy (80% Į, 20% Fe) is one of the most magnetic nickel alloys, with relative permeability exceeding 100,000.