Check Valve Components Foundry

Zkontrolujte ventil: Typy, Aplikace & Selection Guide

Obsah show

1. Zavedení

A check valve is a mechanical non-return device that regulates fluid flow to ensure unidirectional movement in pipelines and systems.

Its core functions include: preventing backflow-induced equipment damage (NAPŘ., pump impeller reversal), mitigating water hammer (pressure surges from sudden flow reversal), maintaining system pressure, and preventing cross-contamination between fluid streams.

Unlike active valves (NAPŘ., gate or ball valves), check valves operate autonomously, responding solely to changes in fluid pressure.

This simplicity makes them reliable in critical systems where failure could result in downtime, safety hazards, or environmental harm—statistics show that 23% of pump failures in industrial settings are attributed to unchecked backflow, underscoring their importance.

2. What Is a Check Valve?

A check valve is a pressure-actuated valve comprising a valve body, a closure element (NAPŘ., disk, míč, piston), and a seating surface.
Its defining feature is the ability to automatically open under forward pressure and close under reverse pressure.
The closure element is designed to seal tightly against the seat when flow reverses, with no external actuation required.
This passive operation eliminates the need for sensors, ovladače, or human intervention, making check valves suitable for remote, hazardous, or inaccessible locations (NAPŘ., subsea pipelines 3,000 meters deep).

Check valves are classified by their closure mechanism and are engineered to accommodate specific flow rates (0.1 na 10,000+ GPM), pressures (vysávat do 25,000 psi), a teploty (-450°F to 1,800°F), ensuring versatility across liquids, plyny, and slurries.

Check Valve Components
Check Valve Components

3. How does a Check Valve Work

Check valves operate on the principle of differential pressure (Δp) between the upstream (inlet) and downstream (outlet) sides:

  • Opening Phase: When upstream pressure exceeds downstream pressure by a threshold known as the “cracking pressure”, the closure element is pushed off its seat, creating an orifice for flow.
    Cracking pressure varies by design—spring-loaded check valves typically require 0.5–5 psi, while gravity-driven swing check valves may need 1–3 psi to overcome inertia.
  • Flow Phase: Once open, the closure element lifts to a maximum displacement (typically 10–20% of the pipe diameter), allowing fluid to pass with minimal pressure drop.
    Streamlined designs (NAPŘ., ball check valves) achieve pressure drops as low as 1 psi na 50 GPM, while more restrictive piston designs may incur 3–5 psi drops.
  • Closing Phase: Když tlak proti proudu klesne pod tlak po proudu (reverse flow), the closure element is forced back onto the seat by reverse pressure, gravitace, or spring tension.
    Closure speed is critical—fast-closing lift check valves (<0.1 sekundy) reduce reverse flow volume by 70% compared to slow-closing swing check valves (0.5–1 second), minimizing water hammer risk.

Fluid properties influence operation: viscous fluids (NAPŘ., heavy crude oil) require lower cracking pressures to overcome internal friction, while abrasive slurries demand robust closure elements (NAPŘ., Stellite-coated discs) to resist wear.

4. Common Types of Check Valves

Check valves come in several designs, each tailored to specific flow conditions, installation constraints, and maintenance priorities.

Swing Check Valves

  • Design: Features a hinged disc (or flap) that swings open under forward flow, pivoting on a pin or hinge mounted inside the valve body.
    When flow stops or reverses, gravity pulls the disc back onto the seat, vytvoření pečeti.

    Zpětný ventil protizávaží
    Swing Check ventil

  • Key Metrics:
    • Flow capacity: Vysoký (Cv values 15–20% higher than lift check valves of the same size). A 6-inch swing check valve, například, has a Cv of ~300, compared to ~250 for a 6-inch lift check valve.
    • Closure time: 0.5–1 second (slower than other types, increasing water hammer risk).
    • Size range: 2–48 inches (ideal for large-diameter pipelines).
  • Výhody: Nízká tlaková ztráta (1–2 psi at nominal flow) and cost-effectiveness for large-scale systems.
  • Omezení: Unsuitable for vertical upward flow (gravity may prevent proper closure); prone to “slamming” in high-velocity systems, causing noise and wear.
  • Aplikace: Municipal water distribution, large-diameter oil/gas pipelines, and low-pressure industrial loops (NAPŘ., cooling water circuits).

Lift Check Valves

  • Design: Uses a piston, disk, or plug that lifts vertically off the seat, guided by a stem or cage to ensure alignment.
    Forward flow pushes the closure element upward, while reverse pressure (aided by gravity or a spring) forces it back down.

    Lift Check Valve Parts
    Lift Check Valve Parts

  • Key Metrics:
    • Leakage rate: <0.1 cc/min (sedadla na kov), achieving ANSI Class IV shutoff.
    • Closure time: <0.1 sekundy (significantly faster than swing valves, reducing water hammer by 50%+).
    • Size range: ½–12 inches (limited by manufacturing complexity for larger diameters).
  • Výhody: Tight shutoff and suitability for high-pressure systems (až do 25,000 psi).
  • Omezení: Vyšší pokles tlaku (3–5 psi at nominal flow) due to the guided design.
  • Aplikace: High-pressure steam lines (1,500+ psi), Hydraulické systémy, and pump discharge lines where backflow could damage impellers.

Spring-Loaded Check Valves

  • Design: Integrates a coil spring that biases the closure element (disc or ball) against the seat.
    The spring force determines the cracking pressure (minimum upstream pressure to open the valve), which can be adjusted by selecting springs with different tension ratings.

    Axial Spring Check Valve
    Spring Check Valve

  • Key Metrics:
    • Praskající tlak: 0.5–50 psi (customizable via spring selection).
    • Orientation flexibility: Operates reliably in vertical, horizontální, or angled pipelines.
    • Closure time: <0.1 sekundy (spring force accelerates sealing).
  • Výhody: Prevents “fluttering” (rapid opening/closing) in low-flow systems; ideal for applications where gravity alone can’t ensure closure.
  • Omezení: Higher pressure drop than non-spring designs (due to spring resistance); spring fatigue may occur in cyclic service (NAPŘ., 10,000+ cykly).
  • Aplikace: Pneumatic systems (vzduch, dusík), palivové potrubí, and boiler feedwater circuits (vertical installation).

Ball Check Valves

  • Design: Employs a spherical ball (typically stainless steel or plastic) that rests on a conical seat.
    Forward flow lifts the ball, allowing fluid to pass around it; reverse flow pushes the ball back into the seat, vytvoření pečeti.

    Ball Check Valves
    Ball Check Valves

  • Key Metrics:
    • Flow efficiency: Vysoký (Cv values 10–15% higher than piston lift check valves). A 2-inch ball check valve has a Cv of ~50, vs.. ~45 for a 2-inch piston design.
    • Abrasion resistance: Mírný (metal balls outperform plastic in slurry service).
  • Výhody: Low friction and minimal turbulence, reducing energy loss.
  • Omezení: Plastic balls deform at temperatures >250° F.; metal balls may stick in viscous fluids (NAPŘ., heavy oils).
  • Aplikace: Chemické zpracování (low-viscosity fluids), food/beverage (sanitary designs with PTFE balls), and irrigation systems.

Pilot-Operated Check Valves

  • Design: Combines a main check valve with a secondary “pilot” valve that controls the main valve’s opening.
    The pilot uses external pressure (from the system or a separate source) to lift the main closure element, allowing flow only when pilot pressure is applied.

    Pilot-Operated Check Valves
    Pilot-Operated Check Valves

  • Key Metrics:
    • Control precision: Can be adjusted to open at specific pressure thresholds (±1 psi).
    • Backflow prevention: Maintains seal even in systems with fluctuating downstream pressure.
  • Výhody: Enables “locked” flow positions (NAPŘ., holding a hydraulic cylinder in place), preventing drift.
  • Omezení: Complex design increases cost (2–3× that of standard check valves); requires compatible pilot pressure sources.
  • Aplikace: Hydraulic machinery (jeřáby, presses), where precise flow control and load holding are critical.

5. Key Performance Parameters and Metrics

  • Cracking Pressure: Minimum ΔP to open the valve (0.5–50 psi). Critical for low-flow systems (NAPŘ., zdravotnické prostředky) where unintended opening must be prevented.
  • Pokles tlaku: Energy loss across the valve, measured at nominal flow. Například, a 2-inch swing check valve has a pressure drop of 2 psi na 100 GPM, while a lift check valve of the same size incurs 3 psi.
  • Leakage Rate: Amount of fluid bypassing the closed valve. Metal-seated valves typically achieve ANSI Class IV (0.01% of nominal flow), while soft-seated valves meet Class VI (<0.0005 mL/min per inch diameter).
  • Closure Time: Time to seal after flow reversal. Spring-loaded valves close in <0.1 sekundy, reducing water hammer pressure spikes by 50% vs.. swing valves.
  • Cycle Life: Number of open/close cycles before failure. Stainless steel valves in clean service last 100,000+ cykly; Stellite-coated valves in abrasive service last 10,000+ cykly.

6. Materiály, Možnosti těsnění, and Media Compatibility

The spolehlivost, service life, and safety compliance of a check valve are heavily influenced by the choice of body material, internal trim components, a sealing elements.

Material selection must be based on chemie tekutin, provozní teplota, tlak, a regulační požadavky.

Brass Check Valves Component
Brass Check Valves Component

Using an incompatible material can cause premature wear, koroze, or seal failure — leading to leakage and unplanned downtime.

Body and Trim Materials

Materiál Max Service Temp (° F.) Odolnost proti korozi Pevnost Běžné aplikace
Litina ~ 450 Low–Moderate Mírný Pitná voda, HVAC, low-pressure water lines
Tažné železo ~ 450 Mírný Higher than cast iron Obecní voda, požární ochrana
Uhlíková ocel (A216 WCB) ~800 Mírný (not for strong acids) Vysoký Steam lines, olej & plyn
Nerez 304 ~1000 Vysoký (general corrosion) Vysoký Jídlo & nápoj, úpravy vody
Stainless Steel 316/316L ~1000 Vynikající (chloridy, kyseliny) Vysoký Chemické zpracování, Marine
Duplex & Super duplex ~600 Exceptional (chloridy, solanka) Velmi vysoká Offshore oil/gas, Odsolování
Bronze/Brass ~ 400 Dobrý (fresh water, mild seawater) Mírný Marine, HVAC, pitná voda
PVC / CPVC ~200 (PVC), ~210 (CPVC) Vynikající (most acids/bases) Nízký Chemické dávkování, odpadních vod
PVDF (Kynar®) ~ 280 Vynikající (chlór, silné kyseliny) Mírný High-purity chemical transfer

Engineering Notes:

  • Pro abrasive slurries, use hard-facing on seating surfaces (Stellite® or tungsten carbide).
  • Pro hydrogen sulfide (H₂s) prostředí, follow NACE MR0175/ISO 15156 material requirements.

Seat and Seal Materials

The sealing element — elastomer or thermoplastic — determines leakage performance, chemická kompatibilita, and temperature limits.

Materiál těsnění Max Service Temp (° F.) Chemická odolnost Typické případy použití
EPDM ~ 300 Excellent in water, pára, jemné kyseliny Pitná voda, HVAC, odpadních vod
NBR (Ahoj-N) ~ 250 Good for oils, paliva Hydrocarbon service, lubricants
FKM (Viton®) ~ 400 Excellent in solvents, kyseliny, paliva Chemikálie & petrochemický
PTFE (Teflon®) ~500 Inert to almost all chemicals High-purity chemicals, jídlo & Pharma
Kov na kov 1000+ Limited by body material High-temp steam, erosive service

Industry Data:

  • Metal-to-metal seats dosáhnout ANSI Class IV or V shutoff in industrial service.
  • Měkká sedadla (Elastomery) can achieve ANSI třída VI (bubble-tight) sealing but are limited by temperature and chemical compatibility.

Media Compatibility Considerations

  • Voda & Pitná voda — EPDM or NBR seats with cast iron, tažné železo, or stainless steel bodies. NSF/ANSI 61 certification required.
  • Mořská voda & Brine — 316SS, duplex stainless, or bronze bodies; EPDM seals; avoid carbon steel due to rapid corrosion.
  • Hydrocarbons & Fuels — NBR or FKM seals; carbon steel or stainless steel bodies.
  • Strong Acids — PTFE seats and liners; 316Ss, PVDF, or lined ductile iron bodies.
  • Pára — Carbon steel or stainless bodies with metal-to-metal seats; EPDM acceptable for low-pressure steam (<300 ° F.).
  • Slurries & Abrasives — Hardened seat materials, full-port ball check designs, wear-resistant coatings.

7. Industry Applications of Check Valve

Check valves are deployed across virtually every fluid-handling industry, with each application imposing unique requirements for tlaková třída, Těsnění, response speed, a kompatibilita materiálu.

Their primary purpose — preventing reverse flow — protects pumps, kompresory, potrubí, and downstream equipment, while ensuring system integrity and compliance with industry regulations.

Voda & Čištění odpadních vod

  • Funkce: Prevent backflow from distribution networks into clean water sources, stop reverse siphoning in pumping stations, and protect membrane filtration units from pressure surges.
  • Typical Configurations: Swing check valves for low head-loss in distribution mains; ball check valves in sludge and slurry lines; spring-assisted valves in high-rise building booster systems.
  • Industry Data: According to AWWA C508, swing check valves in municipal water service typically operate at flow velocities of 2–15 ft/s and pressure ratings of 125–250 psi.
  • Regulatory Standards: NSF/ANSI 61 a 372 for drinking water contact; AWWA C508/C509 compliance.

Olej & Plyn

  • Funkce: Maintain directional flow in crude oil pipelines, prevent backflow into compressors, and isolate sections of offshore risers during shutdowns.
  • Typical Configurations: API 6D swing or dual-plate check valves in transmission pipelines; axial-flow silent check valves to minimize water hammer in gas compression stations.
  • Industry Data: Offshore subsea check valves are designed to API 6A a NACE MR0175, with pressure ratings up to 20,000 psi and temperature ranges from -75°F to +350°F.
  • Key Requirements: Sour-service metallurgy, sand erosion resistance, and low closing times (<0.2 sekundy) for slam prevention.

Výroba energie

  • Funkce: Prevent reverse steam or feedwater flow in turbines, protect boiler feed pumps, and maintain circulation in cooling water loops.
  • Typical Configurations: Lift check valves for high-pressure steam lines; spring-loaded in-line valves in condensate return systems.
  • Industry Data: ASME B31.1-compliant valves in fossil-fuel plants often handle steam at 2,400 psi and 1,050°F; feedwater check valves typically have Třída 1500–2500 pressure ratings.
  • Special Considerations: Metal-to-metal seats, Stellite® hard-facing, and quick-closure mechanisms to prevent turbine backspin.

Chemikálie & Petrochemický

  • Funkce: Prevent contamination between process streams, stop reverse chemical feed into storage tanks, and protect metering pumps.
  • Typical Configurations: PTFE-lined swing or ball check valves for corrosive acids; stainless steel spring-loaded check valves for solvent transfer lines.
  • Industry Data: Valves must often withstand pH 0–14 fluids, chlorine service at up to 150°F, or hydrochloric acid at 30–35% concentration.
  • Regulatory Standards: Compliance with API 594 for wafer-type valves, a ASTM F1545 for PTFE-lined equipment.

HVAC & Building Services

  • Funkce: Prevent reverse flow in chilled water and hot water loops, protect booster pumps, and stop backflow in fire protection systems.
  • Typical Configurations: Silent check valves in vertical risers; wafer dual-plate check valves for space-constrained mechanical rooms.
  • Industry Data: ASHRAE guidelines suggest low head-loss designs (<1.5 psi at design flow) for energy efficiency in HVAC loops.

Marine & Offshore

  • Funkce: Prevent seawater ingress into cooling systems, stop reverse flow in ballast systems, and protect firewater pumps.
  • Typical Configurations: Bronze or duplex stainless swing check valves for seawater service; axial-flow valves for offshore risers.
  • Special Considerations: Resistance to chloride pitting (ASTM G48 testing), shock resistance per MIL-S-901D for naval applications.

Jídlo & Nápoj

  • Funkce: Maintain hygiene by preventing product backflow, avoid contamination between CIP (clean-in-place) and process lines.
  • Typical Configurations: Sanitary clamp-end check valves with 316L stainless and EPDM or PTFE seats.
  • Industry Data: Valves must meet 3-A Sanitary Standards a FDA CFR 21 elastomer requirements; internal surface finishes of ≤32 μin Ra are common.

8. Výhody a omezení

Advantages of Check Valves

  • Autonomous Operation: No external power or controls, reducing failure points (99.9% reliability in clean service).
  • Nákladově efektivní: Lower upfront and maintenance costs vs. active valves (30–50% cheaper than automated control valves).
  • Všestrannost: Adaptable to diverse fluids, pressures, a teploty.
  • Bezpečnost: Prevents equipment damage and environmental spills (critical in chemical processing, where backflow can release toxic substances).

Limitations of Check Valves

  • Pokles tlaku: Incurs energy loss (1–5 psi) that increases pumping costs in high-flow systems.
  • Riziko vodního kladiva: Slow-closing designs (NAPŘ., swing valves) can cause pressure spikes up to 2× system pressure.
  • Size Restrictions: Lift check valves are impractical for diameters >12 inches due to cost and weight.
  • Potřeby údržby: Prone to fouling in dirty fluids (NAPŘ., 25% of check valve failures in wastewater are due to debris buildup).

9. Standardy, Osvědčení

Check valves are not only mechanical components but also compliance-critical devices in many industries.

Their design, výrobní, testování, and material selection are often governed by international, national, and sector-specific standards to ensure safety, performance reliability, and legal conformity.

Norma / Code Rozsah Key Requirements
API 6D / ISO 14313 Pipeline valves for petroleum & zemní plyn Design, materiály, testování (hydrostatic, plyn), označení
API 594 Wafer-type & lug-type check valves Face-to-face dimensions, pressure-temperature ratings
API 6A Wellhead & Christmas tree equipment Sour service, high-pressure oil & gas environments
ASME B16.34 Valves — flanged, závitové, and welding ends Pressure-temperature ratings, material requirements
ASME B31.1 / B31.3 Power piping & process piping Instalace, allowable stress, weld requirements
BS EN 12334 Industrial metallic check valves Design, výkon, and test procedures
AWWA C508 / C509 Swing and resilient-seated check valves for waterworks Povlaky, seat materials, výkonnostní kritéria
MSS SP-125 Šedé železo & ductile iron check valves Dimensions, pressure ratings
ISO 5208 Pressure testing of metallic valves Leakage rates (Class I–VI)

10. Srovnání s jinými ventily

Funkce Zkontrolujte ventil Brána ventil Kulový ventil Tlakový reliéfní ventil
Primární funkce Prevents reverse flow automatically Manual/motorized isolation Quick on/off isolation, some throttling Protects against overpressure
Operation Method Pressure differential, self-acting Manual or actuated stem Quarter-turn manual/actuated Spring or pilot-operated
Směr toku Unidirectional Bidirectional Bidirectional Vents to atmosphere/return line
Flow Control Capability Žádný On/off only On/off + omezené škrcení Žádný (pressure-triggered)
Pokles tlaku Nízká – střední (1–5 psi) Velmi nízké Velmi nízké N/a
Closing Speed
0.05–1 s (type-dependent) Pomalý Instant (¼ turn) Instant upon setpoint
Typical Pressure Rating Až do 25,000 psi ~2,500 psi Až do 10,000 psi Up to system MAWP
Seal Performance Třída IV–VI Class II–IV Bubble-tight with soft seats Leak to relieve pressure
Vyžaduje se aktivaci Žádný Ano (manual/motor) Ano (manual/motor) Žádný (spring/pilot)
Typické aplikace Vypouštění čerpadla, safety isolation from backflow Pipeline isolation Isolation in oil/gas, chemikálie Boiler protection, safety systems
Maintenance Demand Nízký Nízká – střední Mírný Nízký
Special Features Fully automatic Full bore, low loss Fast action, compact Prevents catastrophic overpressure

11. Check Valve Selection & Procurement Checklist

Before placing an order for a check valve, it is essential to comprehensively document all critical parameters to ensure the selected valve meets system requirements and operates reliably throughout its service life.

The following checklist outlines the key factors to record and evaluate:

Charakteristika kapaliny

  • Identify the fluid type (voda, pára, olej, plyn, chemikálie, kaše, atd.).
  • Document temperature range (minimum to maximum operating temperatures).
  • Note any chemical properties such as corrosiveness, pH level, and presence of abrasives or contaminants.

Pressure Requirements

  • Record the maximum operating pressure (MOP) under normal conditions.
  • Verify the Maximum Allowable Working Pressure (MAWP) as per system design and safety margins.

Flow Rate and Hydraulic Performance

  • Determine required flow rate to be handled by the valve (NAPŘ., gallons per minute or cubic meters per hour).
  • Specify maximum allowable pressure drop across the valve, which relates to the desired flow coefficient (CV).

Leakage and Sealing Criteria

  • Define maximum acceptable leakage rate according to seat class (NAPŘ., ANSI/FCI Class IV for low leakage or VI for bubble-tight sealing).
  • Decide between soft or metal seating based on application demands.

Solids and Viscosity Considerations

  • Assess if the fluid contains solids or particulate matter and their size.
  • Evaluate fluid viscosity and its impact on valve operation and sealing.

Dimensional and Connection Details

  • Confirm pipeline nominal size and required valve size.
  • Specify connection type: přírubové (ANSI/ASME B16.5), závitové, socket weld, butt weld, or other.

Installation and Orientation Constraints

  • Document valve orientation requirements (horizontální, vertical, or inclined).
  • Record face-to-face dimensions and available installation clearance to ensure fit and ease of maintenance.

Environmental and External Conditions

  • Consider external environmental factors such as corrosion risks, exposure to weather, possibility of burial or subsea installation.
  • Specify any special coatings, materiály, or design features needed for harsh environments.

Standards and Certification Requirements

  • Identify applicable industry standards (API, ANSI, ISO, ASME) and regulatory certifications (NSF, PED, UL/FM, NACE).
  • Ensure the valve meets all quality and compliance benchmarks relevant to the application.

Maintenance and Support Considerations

  • Evaluate accessibility for routine maintenance, inspekce, and repair.
  • Confirm availability of spare parts, repair kits, and technical support from the supplier.

12. Závěr

Check valves come in various designs—from swing to pilot-operated valves—and serve a wide range of industries, from oil and gas to pharmaceuticals, ensuring safety, účinnost, and regulatory compliance.

By understanding key performance factors, materiálová kompatibilita, and applicable standards, engineers can choose the right check valve to reduce downtime and extend system life.

As industry demands grow for higher pressures, teploty, a udržitelnost, check valves will continue evolving, with innovations like smart sensors and advanced manufacturing techniques further improving their performance.

TENTO: Vysoce přesná řešení odlévání ventilu pro náročné aplikace

TENTO provides high-precision valve casting solutions designed for the most demanding industrial applications where reliability, Integrita tlaku, and dimensional accuracy are critical.

Offering comprehensive end-to-end services—from raw castings to fully machined valve bodies and assemblies—TENTO ensures every component meets stringent global quality standards.

Naše odborné znalosti odlévání ventilů zahrnují:

  • Investiční obsazení: Utilizing advanced lost wax technology to create complex internal geometries and tight-tolerance valve components with superior surface finishes, ideal for precision valve bodies and trims.
  • Písek and Shell Mold Casting: Cost-effective methods perfect for medium to large valve bodies, příruby, and bonnets, widely used in rugged sectors such as oil & Výroba plynu a energie.
  • Přesné obrábění CNC: Accurate machining of seats, vlákna, and sealing surfaces guarantees dimensional accuracy and optimal sealing performance for every casting.
  • Material Versatility: Supplying a broad range of materials including stainless steels (CF8, CF8M, CF3, CF3M), mosaz, tažné železo, Duplex, and high-alloy alloys to withstand corrosive, vysokotlaký, and high-temperature conditions.

Whether your project demands custom butterfly valves, Zkontrolujte ventily, Globe ventily, brány ventily, or high-volume industrial valve castings, TENTO stands as a trusted partner committed to precision, trvanlivost, a zajištění kvality.

Contact Us Today!

Časté časté

What does a check valve do?

It stops backflow, protecting equipment and maintaining correct flow direction.

How to check PCV valve?

Remove it and shake — a working PCV valve usually rattles. Also check for vacuum at idle; no vacuum may indicate clogging.

What is the difference between a check valve and a control valve?

Zkontrolujte ventily provozují pasivně, allowing flow in one direction only, while control valves require external actuation to regulate flow rate, tlak, or direction.

Can check valves be installed vertically?

Ano, but spring-loaded designs are required to ensure closure (gravity alone may fail in vertical lines). Swing check valves should be mounted horizontally.

How do I select the right check valve for my system?

Consider fluid type (viskozita, abrasiveness), pressure/temperature, pipe size, and required cracking pressure.

For high-pressure, tight-shutoff applications, lift check valves are preferred; for large diameters, swing check valves offer better flow capacity.

What causes water hammer, and how can check valves prevent it?

Water hammer is caused by sudden flow reversal. Fast-closing check valves (NAPŘ., spring-loaded or lift designs) minimize reverse flow volume, reducing pressure spikes.

How long do check valves last?

In clean service, 10–15 years; in abrasive or corrosive environments, 3–5 years with proper maintenance. Material selection (NAPŘ., Hastelloy vs. Uhlíková ocel) significantly impacts service life.

Přejděte na vrchol