1. Tabhairt isteach
Effective fluid control depends on selecting the right valve for the job. De thoradh, engineers rely on valve size comparison tables to translate between different standards, compare dimensional data, and verify compatibility.
Sa chuid seo, we clarify the article’s scope, underscore why accurate valve sizing matters, and define what a valve size comparison table is—and why it proves so useful in daily practice.
- Purpose and scope: We aim to equip process, meicniúil, and piping engineers with a comprehensive guide to creating and using valve size comparison tables.
- Importance of accurate sizing: Mis-sized valves can cause up to a 15% drop in process efficiency, lead to premature wear, or even provoke system failures. I gcodarsnacht, correctly sized valves optimize flow, tomhaltas fuinnimh a laghdú, and extend equipment life.
- Overview of comparison tables: Ina chroílár, a valve size comparison table aligns Nominal Pipe Size (NPS) or Diameter Nominal (DN) designations with actual bore diameters, face-to-face dimensions, flange details, and related parameters.
By doing so, it enables quick cross-referencing across ANSI, Ó, An duine, Iso, and other standards.
2. Fundamentals of Valve Sizing
Before designing or interpreting a comparison table, one must grasp basic sizing concepts.
Thíos, we contrast nominal versus actual sizes, identify critical dimensional parameters, and explain how these factors influence flow and performance.

Nominal Pipe Size (NPS) vs. Actual Bore (ID)
- NPS denotes a standardized label (E.g., NPS 4), but it does not equal the internal diameter.
- Actual Bore (ID) varies by manufacturer and standard: mar shampla, NPS 4 typically has an ID of 4.026 le linn (102.3 mm) in ANSI valves but may differ under DIN or JIS specifications.
Key Dimensional Parameters
- Face-to-Face (F2F): Distance between valve ends—critical for pipeline layout.
- End-to-End (E2E): Similar to F2F but sometimes used for wafer or lug-type valves.
- Flange Dimensions: Outer diameter (OD), bolt-circle diameter (BCD), bolt hole count and size.
Impact on Flow and Performance
Valve sizing heavily influences pressure drop (Δp) and flow coefficient (CV).
Mar shampla, upsizing a valve by one NPS can increase Cv by roughly 20–25%, thereby reducing energy losses in high-flow applications.
3. International and Industry Standards
Global operations demand seamless interoperability. Ar an dóigh sin, engineers must navigate multiple standard bodies:
| Standard Body | Key Documents | Brúranganna |
|---|---|---|
| ANSI/ASME (SAM) | B16.10, B16.5 | 150#, 300#, 600#, sreoir. |
| DIN EN (An Eoraip) | Le linn 558, PN classes | Pn 6, Pn 10, Pn 16, Pn 40 |
| An duine (An tSeapáin) | B2239 (F2F), B2002 (flanges) | 5K, 10K, 16K, 20K |
| Iso (Global) | 5752, 7005 | Sraith 1, Sraith 2 |
4. Gate Valve Size Comparison Table
Standards Referenced: ASME B16.10, ASME B16.5 (Áirigh ar 150), Le linn 558, Le linn 1092-1 (PN16)
Cineál comhla: Bándáilte, Full-Port Gate Valve
Material Assumed: Cruach charbóin (WCB), Rising Stem Design
| NPS (le linn) | DN (mm) | Actual Bore (ID, mm) | Face-to-Face (mm) | Flange OD (mm) | Bolt Circle Ø (mm) | Níl. of Bolts | Bolt Hole Ø (mm) |
|---|---|---|---|---|---|---|---|
| 2 | 50 | 51 | 178 | 152 | 120.5 | 4 | 19 |
| 2½ | 65 | 64 | 190 | 178 | 139.7 | 4 | 19 |
| 3 | 80 | 76 | 203 | 190 | 152.4 | 4 | 19 |
| 4 | 100 | 102 | 229 | 229 | 190.5 | 8 | 19 |
| 5 | 125 | 127 | 254 | 254 | 216 | 8 | 22 |
| 6 | 150 | 152 | 267 | 279 | 241.3 | 8 | 22 |
| 8 | 200 | 203 | 292 | 343 | 298.5 | 8 | 22 |
| 10 | 250 | 254 | 330 | 406 | 362 | 12 | 25 |
| 12 | 300 | 305 | 356 | 483 | 431.8 | 12 | 25 |
| 14 | 350 | 337 | 381 | 533 | 476.3 | 12 | 29 |
| 16 | 400 | 387 | 406 | 597 | 539.8 | 16 | 29 |
| 18 | 450 | 438 | 432 | 635 | 577.9 | 16 | 32 |
| 20 | 500 | 489 | 457 | 699 | 635 | 20 | 32 |
| 24 | 600 | 591 | 508 | 813 | 749.3 | 20 | 35 |
Nótaí:
- Actual Bore (ID) may vary slightly depending on manufacturer and trim style; values are typical for full-port design.
- Face-to-Face values follow ASME B16.10 or EN 558 Sraith 1.
- Flange OD, Bolt Circle, is Bolt Dimensions follow ASME B16.5 Class 150 / Le linn 1092-1 PN16 as applicable.
- All dimensions are in millimeters unless otherwise noted.
- Custom valve designs or higher pressure classes (Áirigh ar 300, PN25) will require different flange and body dimensions.
5. Butterfly Valve Size Comparison Table
Cineál comhla: Wafer-style Soft Seal Butterfly Valve
Caighdeáin: Le linn 558 Sraith 20 (Face-to-Face), Le linn 1092-1 (Flange), ASME B16.5 Class 150 Flains
Rátáil Brú: Pn10 / PN16 / ANSI Class 150
| DN (mm) | NPS (le linn) | Face-to-Face (mm) | Flange Outer Diameter (OD, mm) | Bolt Circle Diameter (BCD, mm) | Number of Bolt Holes | Bolt Hole Diameter (mm) |
|---|---|---|---|---|---|---|
| 50 | 2 | 108 | 165 | 125 | 4 | 18 |
| 65 | 2½ | 114 | 185 | 145 | 4 | 18 |
| 80 | 3 | 127 | 200 | 160 | 8 | 18 |
| 100 | 4 | 140 | 220 | 180 | 8 | 18 |
| 125 | 5 | 152 | 250 | 210 | 8 | 18 |
| 150 | 6 | 165 | 285 | 240 | 8 | 22 |
| 200 | 8 | 191 | 340 | 295 | 8 | 22 |
| 250 | 10 | 216 | 395 | 350 | 12 | 22 |
| 300 | 12 | 241 | 445 | 400 | 12 | 22 |
| 350 | 14 | 267 | 505 | 460 | 16 | 22 |
| 400 | 16 | 292 | 565 | 515 | 16 | 26 |
| 450 | 18 | 318 | 620 | 565 | 20 | 26 |
| 500 | 20 | 343 | 670 | 620 | 20 | 26 |
| 600 | 24 | 394 | 780 | 725 | 20 | 30 |
Additional Notes:
- Face-to-Face dimensions per EN 558 Sraith 20 wafer design ensure compatibility with flanges rated PN10/PN16 or ANSI Class 150.
- Flange dimensions (OD, bolt circle, bolt holes) conform to EN 1092-1 or ASME B16.5 to ensure proper installation between pipe flanges.
- Bolt hole size and number correspond with flange class and size to maintain pressure integrity.
- Soft seal butterfly valves use elastomeric liners (EPDM, NBR, Fíor) and are preferred for water, HVAC, and light chemical services.
6. Flange Type Soft Seal Butterfly Valve Size Comparison Table
Cineál comhla: Flanged Soft Seal Butterfly Valve
Caighdeáin: Le linn 558 Sraith 20 (Face-to-Face), Le linn 1092-1 (Flanges PN10/16), ASME B16.5 Class 150 Flains
Pressure Class: PN10/PN16 / ANSI Class 150
| DN (mm) | NPS (le linn) | Face-to-Face (mm) | Flange Outer Diameter (mm) | Bolt Circle Diameter (mm) | Number of Bolt Holes | Bolt Hole Diameter (mm) |
|---|---|---|---|---|---|---|
| 50 | 2 | 140 | 165 | 125 | 4 | 18 |
| 65 | 2½ | 152 | 185 | 145 | 4 | 18 |
| 80 | 3 | 165 | 200 | 160 | 8 | 18 |
| 100 | 4 | 178 | 220 | 180 | 8 | 18 |
| 125 | 5 | 191 | 250 | 210 | 8 | 18 |
| 150 | 6 | 203 | 285 | 240 | 8 | 22 |
| 200 | 8 | 229 | 340 | 295 | 8 | 22 |
| 250 | 10 | 254 | 395 | 350 | 12 | 22 |
| 300 | 12 | 279 | 445 | 400 | 12 | 22 |
| 350 | 14 | 305 | 505 | 460 | 16 | 22 |
| 400 | 16 | 330 | 565 | 515 | 16 | 26 |
| 450 | 18 | 356 | 620 | 565 | 20 | 26 |
| 500 | 20 | 381 | 670 | 620 | 20 | 26 |
| 600 | 24 | 432 | 780 | 725 | 20 | 30 |
Nótaí:
- Face-to-Face dimension corresponds to EN 558 Sraith 20 flanged butterfly valve standard, suitable for installation between flanges rated PN10/PN16 or ANSI Class 150.
- Flange OD, Bolt Circle Diameter, Bolt Hole Qty and Size conform to EN 1092-1 and ASME B16.5 to ensure compatibility with standard pipe flanges.
- Soft seal typically uses elastomers like EPDM, NBR, óir Viton, providing excellent sealing for water, aer a ligean isteach i, and light chemical applications.
- Flange butterfly valves allow easy removal/replacement without disturbing pipeline flanges.
7. Butterfly Valve Dimensions under EN Standard
Caighdeánach: Le linn 558 (Face-to-Face) & Le linn 1092-1 (Flange)
Cineál comhla: Wafer/Flanged, Soft Seal
Pressure Class: Pn10 / PN16
| DN (mm) | Face-to-Face Length (mm) | Flange Outer Diameter (mm) | Bolt Circle Diameter (mm) | Number of Bolt Holes | Bolt Hole Diameter (mm) |
|---|---|---|---|---|---|
| 50 | 108 | 165 | 125 | 4 | 18 |
| 65 | 114 | 185 | 145 | 4 | 18 |
| 80 | 127 | 200 | 160 | 8 | 18 |
| 100 | 140 | 220 | 180 | 8 | 18 |
| 125 | 152 | 250 | 210 | 8 | 18 |
| 150 | 165 | 285 | 240 | 8 | 22 |
| 200 | 191 | 340 | 295 | 8 | 22 |
| 250 | 216 | 395 | 350 | 12 | 22 |
| 300 | 241 | 445 | 400 | 12 | 22 |
| 350 | 267 | 505 | 460 | 16 | 22 |
| 400 | 292 | 565 | 515 | 16 | 26 |
| 450 | 318 | 620 | 565 | 20 | 26 |
| 500 | 343 | 670 | 620 | 20 | 26 |
| 600 | 394 | 780 | 725 | 20 | 30 |
Explanation:
- Face-to-Face Length: Per EN 558 Sraith 20, applies to wafer and lug butterfly valves.
- Flange Outer Diameter, Bolt Circle Diameter, Bolt Hole Number/Size: Based on EN 1092-1 flange standards for PN10 and PN16 pressure classes.
- These dimensions ensure compatibility with corresponding pipe flanges and facilitate installation.
- An bolt hole pattern ensures proper mechanical strength and sealing integrity.
8. Ball Valve Size Standards Table
ANSI dimensions reflect American standards; EN dimensions reflect European standards.
Standards Referenced: Based on ANSI / ASME Standards
Standards Referenced:
- ASME B16.10 – Face-to-face and end-to-end dimensions
- ASME B16.5 – Flanged connections (for pressure classes 150–2500)
- ASME B16.34 – Valve design, ábhair, and pressure–temperature ratings
| DN (mm) | NPS (le linn) | Face-to-Face (mm) ANSI/ASME B16.10 | Flange OD (mm) ANSI B16.5 Class 150 | Bolt Circle Diameter (mm) ANSI B16.5 | Number of Bolts | Bolt Hole Diameter (mm) | Face-to-Face (mm) Le linn 558 | Flange OD (mm) Le linn 1092-1 PN16 | Bolt Circle Diameter (mm) Le linn 1092-1 | Number of Bolts EN 1092-1 | Bolt Hole Diameter (mm) Le linn 1092-1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 50 | 2 | 152 | 165 | 125 | 4 | 18 | 140 | 185 | 145 | 4 | 18 |
| 65 | 2½ | 165 | 190 | 145 | 4 | 18 | 152 | 200 | 160 | 8 | 18 |
| 80 | 3 | 178 | 215 | 160 | 8 | 18 | 165 | 220 | 180 | 8 | 18 |
| 100 | 4 | 190 | 254 | 180 | 8 | 18 | 178 | 250 | 210 | 8 | 18 |
| 125 | 5 | 216 | 279 | 210 | 8 | 22 | 191 | 285 | 240 | 8 | 18 |
| 150 | 6 | 241 | 324 | 241 | 8 | 22 | 216 | 320 | 295 | 8 | 22 |
| 200 | 8 | 292 | 406 | 362 | 8 | 22 | 267 | 405 | 355 | 8 | 22 |
| 250 | 10 | 330 | 483 | 432 | 12 | 25 | 292 | 460 | 410 | 12 | 22 |
| 300 | 12 | 356 | 559 | 483 | 12 | 25 | 318 | 515 | 460 | 12 | 22 |
| 350 | 14 | 394 | 597 | 539 | 16 | 29 | 343 | 565 | 515 | 16 | 22 |
| 400 | 16 | 432 | 673 | 595 | 16 | 29 | 368 | 620 | 565 | 16 | 26 |
| 450 | 18 | 483 | 698 | 622 | 20 | 32 | 394 | 675 | 615 | 20 | 26 |
| 500 | 20 | 508 | 749 | 673 | 20 | 32 | 419 | 730 | 670 | 20 | 26 |
| 600 | 24 | 584 | 864 | 787 | 20 | 35 | 483 | 840 | 780 | 20 | 30 |
Explanation:
- Face-to-Face: Length between valve ends, critical for pipe fitting.
- Flange Outer Diameter (OD) is Bolt Circle Diameter determine flange compatibility.
- Number and size of bolts depend on flange size and pressure rating.
- Differences may require adapters or custom flanges in international projects.
9. Anailís Il-Pheirspictíochta
Cruinneas tríthoiseach
Lamháltais daingean (±1% on bore, ±2 mm on face-to-face) reduce mis-alignment during installation.
Chomh maith leis sin, accurate dimensions ensure proper gasket compression, preserving seal integrity under pressures up to 250 bac a chur ar.
Comhoiriúnacht ábhair
Material selection—carbon steel, Cruach dhosmálta, or specialized alloys—often modifies wall thickness and overall dimensions.
Mar shampla, stainless valves may feature 5% thicker walls to allow for corrosion allowances, thereby slightly altering nominal F2F dimensions.
Pressure–Temperature Ratings
Valve body ratings must align with flange ratings.
Mar shampla, an ANSI 300# comhla (maximum working pressure 74 bar at 100 ° C) pairs with 300# flanges featuring larger bolt circles (216 mm vs. 184 mm for 150#), necessitating a separate table column for pressure class.
Application-Specific Considerations
- Petrochemical vs. water treatment vs. HVAC: Aggressive media in petrochemical plants often require special alloys and tighter tolerances; i gcodarsnacht, HVAC valves may follow looser ANSI 150# specs.
- Sanitary (tri-clamp) vs. industrial flanges: Tri-clamp fittings use butt-welded or clamp end connections and typically depart from ANSI/DIN bolt patterns entirely,
warranting a specialized mini-table.
Cost and Supply-Chain Implications
Standard valves (90% of market demand) enjoy shorter lead times (2–4 weeks) and lower unit cost.
Cén dóigh faoin spéir a ...?, custom sizes or special materials can stretch lead times to 12–16 weeks and increase cost by 30–50%.
De thoradh, stocking popular sizes (E.g., NPS 2, 4, 6) reduces downtime risk and lowers inventory carrying costs.
10. Deireadh
Accurately sizing valves and translating between standards plays a pivotal role in safeguarding plant reliability, optimizing performance, and controlling costs.
By constructing a well-organized valve size comparison table—complete with essential dimensions, pressure classes, and material notes,
Engineering teams can streamline design reviews, accelerate procurement, and minimize installation errors.
Ar deireadh thiar, investing time in building and maintaining these tables yields dividends in reduced downtime, enhanced safety, and improved operational efficiency.
Different valve manufacturers may have slight variations based on standard dimensions.
When selecting valves in practice, it is essential to consider the specific project requirements, pipeline system parameters, and the product specifications provided by the manufacturer to ensure accurate selection and proper installation.
Seo an rogha iontach é do do riachtanais déantúsaíochta má theastaíonn ardchaighdeán uait comhpháirteanna comhla.



